2.2.2 Installing and Connecting the Readers

The readers must be mounted near each door and connected directly to the door
module(s) in the controller. Each door module can control up to two readers. The
supported reader formats are Wiegand and RS-232.
RS-232 Connection
Connect the RS-232 wires from the reader to the terminal block on the door module. You
can either connect the wires from the reader to Pin 3 ~ 7 (Door 1) or Pin 19 ~ 23 (Door 2)
on the terminal block.
19
20
21
22
23
Door module
Wiegand Connection
Connect the Wiegand wires from the reader to the terminal block on the door module.
You can either connect the wires from the reader to Pin 1 ~ 5 (Door 1) or Pin 17 ~ 21
(Door 2) on the terminal block.
Figure 2-8
Red
+12V
3
Black
GND
4
Yellow
Reader Ctrl
5
Blue
RX
6
TX
Gray
7
Figure 2-7
17
NAV IP Access Controller
2
3
1
A B C
D E F
4
5
6
G H I
J K L
M N O
7
8
9
PQRS
T U V
WXYZ