EverFocus EFC304 User Manual page 27

Nav ip access controller
Hide thumbs Also See for EFC304:
Table of Contents

Advertisement

Door module
• Magnetic Lock
Connect the wires from the magnetic lock to the terminal block on the door module.
You can either connect the wires to Pin 12 and 13 (Door 1) or Pin 28 and 29 (Door 2)
on the terminal block.
28
29
Door module
Note:
1. The maximum current output of the door lock relay is 5A. If the current of the
door lock is over this value, an external power relay will be required.
2. When using a DC power source to power the lock, connect the positive lead to
V+. When using an AC power source, the leads are interchangeable.
Connecting to the Door Sensor
Connect the wires from the door sensor to the terminal block on the door module. You
can either connect the wires to Pin 9 and 10 (Door 1) or Pin 25 and 26 (Door 2) on the
terminal block.
27
11
28
12
COM
Figure 2-9
V-
COM
12
13
N.C.
Figure 2-10
9
25
26
10
Door module
Figure 2-11
.
N.O
V-
V+
V+
GND
Input Signal
19
NAV IP Access Controller
Door sensor

Advertisement