Note: Among the No.7, 9, 11 and 13 extension wires, No.11 extension wire is the common
ground terminal of alarm input, door status switch and door open button.
2.2.2.4 Connecting to the Door Open Button
The controller provides the interface of the door open button. The door open button is
connected with the No.9 extension wire on the back plate of the controller, and the ground
terminal is connected with the No.11 extension wire.
2.2.3 Connecting to the Alarm Input / Output
2.2.3.1 Connecting to the Fire Alarm / Alarm Input
The controller only provides one path of alarm input (the alarm input can be set to be fire
alarm input or other alarm input). The input terminal is connected with the No.7
extension wire on the back plate of the controller, and the ground terminal is connected
with the No.5 extension wire.
NAV Series TCP/IP Standalone Network Access Controller
13
11
Figure 2-6
11
9
Figure 2-7
Alarm input
GND
7
5
Figure 2-8
11
Door status
switch
Door open
Alarm sensor