Configuring I/O
6.3 Inserting the SINUMERIK I/O module PP72/48
6.3
Inserting the SINUMERIK I/O module PP72/48
Requirement
● The respective PROFIBUS GSD file or PROFINET GSDML file is installed.
See: Installing general station description files for SINUMERIK I/O (Page 142)
● The network view is active.
Procedure
Proceed as follows to insert a PP72/48 I/O module:
1. In the hardware catalog, navigate to the respective device:
– PP72/48 (PROFIBUS): "Further field devices > PROFIBUS DP > NC/RC > SIEMENS
– PP72/48 (PROFINET): "Further field devices > PROFINET IO > I/O > SIEMENS AG >
2. Use drag-and-drop to move the PP72/48 from the hardware catalog to the network view.
3. Interconnect the inserted SINUMERIK I/O with the NCU.
See TIA Portal online help, search term "Interconnect devices in the network view"
144
AG > MOTION CONTROL"
SINUMERIK > PP72/48"
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325