Match Values Between Profinet Io And Profibus Integrated; Assigning Drive Addresses To The Ncu Machine Data - Siemens SINUMERIK 840D sl Configuration Manual

Sinumerik step 7 toolbox v14 sp1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

4.5.11

Match values between PROFINET IO and PROFIBUS Integrated

In case you have used different values, an error message will be issued in the "Info >
Compile" inspector window during the compilation.
The following values must agree:
Isochronous mode values:
● "PLC > Alarms > Isochronous alarms > NCK > Application cycle"
● "PROFINET IO system > Domain management > Sync domains > Sync-Domain_1 >
Send clock"
● "PROFIBUS Integrated_1 > Equidistance > DP cycle > Equidistant DP cycle"
Ti/To values:
● "PROFIBUS Integrated_1 > Equidistance > Ti/To values of the PROFIBUS"
● "I/O device > PROFINET interface [x1] > Extended options > Isochronous mode"
Match the values and compile the project again.
4.5.12

Assigning drive addresses to the NCU machine data

Procedure
To enter configured addresses in the machine data in the TIA Portal, proceed as follows:
1. Check in the TIA Portal which addresses you have assigned to the drives (see
Configuring IO modules or drive telegrams (Page 94)).
2. Transfer the addresses to the machine data (e.g. via SINUMERIK Operate).
See Adapting I/O start addresses (Page 124).
Further information
● General information concerning this machine data is available in Chapter A4 of the
SINUMERIK 840D sl Supplementary Functions Manual: Digital and analog NCK I/Os for
SINUMERIK 840D sl.
● Specific information on the individual machine data can be found in the online help of
SINUMERIK Operate.
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325
Configuring networks
4.5 Configuring PROFINET IO with IRT