Safety configuration
9.8 Configuring Safety Integrated plus (F-PLC)
9.8.3
Creating a second F-runtime group for Safety Integrated plus (F-PLC)
An F-runtime group is automatically created when you activate Safety Integrated plus (F-
PLC) mode. The "Program blocks" folder contains the created F-blocks of the F-runtime
group: CYC_INT5 [OB35], Main-Safety [FB1010] and Main-Safety_DB [DB1010].
The procedure how you can create a second F-runtime group is described below, e.g. to
organize fast-running safety-oriented program sections in a dedicated F-runtime group.
Characteristic SINUMERIK-specific features are described in particular. Detailed information
can be found in the SIMATIC Safety help, Chapter "Defining F-runtime groups".
Procedure
To create a second F-runtime group, proceed as follows:
1. In the project tree, double-click the command "Safety administration", e.g. under "CNC_1
> PLC_1".
2. In the Safety Administration Editor, select the "F-runtime group" entry in the sector tree.
3. Click "Create new F-runtime group".
The "Add new F-runtime group for PLC_1" dialog opens.
Figure 9-11
"Add new F-runtime group for PLC_1" dialog
196