Configuring Safety Integrated Plus (F-Plc) - Siemens SINUMERIK 840D sl Configuration Manual

Sinumerik step 7 toolbox v14 sp1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Safety configuration

9.8 Configuring Safety Integrated plus (F-PLC)

9.8.2
Configuring Safety Integrated plus (F-PLC)
The following sample handling overview illustrates the features for the configuring of Safety
Integrated plus (F-PLC) with a SINUMERIK NCU compared to a CPU S7-300.
Consequently, the overview serves only as an introduction to the configuring and
programming of STEP 7 Safety Advanced with SINUMERIK.
Therefore, observe the following documentation prior to configuring Safety Integrated plus
(F-PLC):
● SIMATIC Safety - Configuring and Programming
● SIMATIC Safety - Getting Started
● SINUMERIK Safety Integrated plus Function Manual
Depending on the application area, the SINUMERIK NCU, being a part of plants and
systems, requires the observance of special standards and regulations. Observe the
appropriate safety and accident prevention regulations, e.g. IEC 60204-1 (general
requirements placed on the safety of machines).
This sample handling overview serves only as an introduction to the configuring and
programming of STEP 7 Safety Advanced with SINUMERIK. It cannot always be used for
effective regular operation. Before you do this, ensure that you reference the current
version of the "SIMATIC Safety - Configuring and Programming " manual. The warnings
and other notes contained in that manual must be observed, even when they are not
repeated in this document!
The non-observance of these regulations can lead to severe injuries and damage to
machines and equipment.
Requirement
● The "SIMATIC STEP 7 Safety Advanced" option package has been installed and
licensed.
● A project is created in the TIA Portal and an NCU added.
Example handling overview
Step
Description
1
Activate the SINUMERIK Safety Integrated plus (F-PLC) mode in the NCU properties (Page 164).
With the activation of the F-capability of the NCU, among other things, an F-execution group is created and tele-
grams are inserted for PROFIsafe and SIC/SCC.
2
Add the desired components (e.g. peripheral device, drive device, NX module, etc.).
See: Insert NX module (Page 21), insert SINUMERIK I/O (Page 139), insert device (Page 17).
3
In the network view, interconnect the peripheral device or drive device with the PROFINET interface X150 of the
NCU.
194
WARNING
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325