Configuring telegrams and drive units
5.6 Displaying or adapting the telegram configuration
Parameter
Drive
NCU/NX device version and the Safety Integrated mode (Page 164) that is set. The selectable
Telegram (PROFIsa-
telegram types depend on the purpose of the telegram.
fe)
F address
PROFIsafe address of the destination
(F_Dest_Add). The address is used for clear identifi-
(only PROFIsafe)
cation of the destination.
Slot
Slot in the device
Start address
Display of the process data word (PZD)
Length
Length of the telegram in bytes or words. The telegram length depends on the telegram type used.
Extension
Display of the extension of the relevant telegram in words or setting, if supported by the telegram
type.
Consistency
The use of various consistency areas is useful to optimize the performance of an S7-CPU. Con-
sistency areas that are longer than two words must be edited with system functions. You can use
the effective Load/Transfer commands for consistency areas up to two words.
Total length:
The consistency applies for all data of this slot. This default entry should usually be sufficient.
Unit:
The consistency applies for one process data word.
You must configure at least a "2" word "Total length" for the transfer of a double word.
Process image
Display of the process image (partition), which is used to consistently transfer the data.
Interrupt OB number
Specification of the interrupt OB number for the output of diagnostic information.
Manual assignment
If this option is activated, you have the capability of assigning the F-monitoring time manually. Oth-
of the F-Watchdog
erwise the F-monitoring time will be assigned according to the global parameterization at the inter-
time
face (DP interface > F-parameters).
(only PROFIsafe)
F-monitoring time
Monitoring time in the fail-safe DP standard slave/IO standard device/PA field device.
(only PROFIsafe)
A valid, current safety telegram must arrive from the F-CPU within the monitoring time. This en-
sures that failures and errors are detected and the appropriate reactions triggered to keep the safe-
ty system in a safe state or to transfer it to a safe state.
Manual assignment
If this option is activated, you have the capability of assigning the F-I/O DB-number manually.
of the F-I/O DB
Otherwise it is assigned by the F system.
number
(only PROFIsafe)
114
Telegrams for PROFIdrive communication (Page 120)
PROFIsafe telegrams (Page 122)
Additional PROFIdrive telegrams for Safety Integrated plus (F-PLC) (Page 123)
Additional PROFIdrive telegrams for Safety Integrated (SPL) (Page 121)
Controller
PROFIsafe address of the source
(F_Source_Add). The address is used for
clear identification of the source.
-
Currently set start address for the configured
module. You can accept or change the ad-
dress.
If you change the start address for an actual
value, the start address is also adapted for
the setpoint.
Only PROFIsafe: The start address is part of
the F-I/O DB-name of this telegram. If you
change the start address, the F-I/O DB-
number will also be changed.
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325