Configuring networks

4.3 Configuring Integrated PROFIBUS (DP Integrated)

4.3
Configuring Integrated PROFIBUS (DP Integrated)
Procedure
To check the PROFIBUS addresses, proceed as follows:
1. In the network view, click the DP Integrated interface of the PLC or select the interface in
the device overview.
2. In the "Properties" tab, in the inspector window, select the entry "PROFIBUS address".
Result
The DRIVE-CLiQ sockets of the real hardware are displayed to which the NX modules must
be connected.
Note
Cycle clock settings
You can only make the cycle clock settings on the PROFIBUS Integrated subnet and not
directly on the interface: For the selected subnet, you find the cycle clock settings under
"Equidistance" in the inspector window.
Observe the rules for setting the clock cycle at the field buses (see Commissioning Manual,
"Commissioning CNC: NCK, PLC, drive").
82
SINUMERIK STEP 7 Toolbox V14 SP1
Configuration Manual, 05/2017, A5E41846325