Accessories - Endress+Hauser Proline Prosonic Flow 93 Operating Instructions Manual

Foundation fieldbus ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 93:
Table of Contents

Advertisement

Accessories

92
8
Accessories
Various accessories, which can be ordered separately from Endress+Hauser, are available for the
transmitter and the sensor. The Endress+Hauser service organization can provide detailed
information on the order codes on request.
Device-specific accessories
Accessory
Description
Wall-mount housing,
Transmitter for replacement or for stock. Use the order code to
transmitter
define the following specifications:
Prosonic Flow 93
• Approvals
• Degree of protection/version
• Cable entry
• Display / power supply / operation
• Software
• Outputs / inputs
Conversion kit,
Conversion kit with appropriate plug-in point modules for
inputs/outputs
converting the current input/output configuration to a new
version.
Sensor P
DN 15 to 65 (½ to 2½")
(DN 15 to 65 /
• –40 to +100 °C (–40 to +212 °F)
½ to 2½")
• –40 to +150 °C (–40 to +302 °F)
Clamp-on version
Sensor P
DN 50 to 300 (2 to 12")
(DN 50 to 4000 /
• –40 to +80 °C (–40 to +176 °F)
2 to 160")
• –40 to +170 °C (–40 to +338 °F)
Clamp-on version
DN 100 to 4000 (4 to 160")
• –40 to +80 °C (–40 to +176 °F)
• –40 to +170 °C (–40 to +338 °F
Sensor W
DN 15 to 65 (½ to 2½"), –40 to +80 °C (–4 to +176 °F),
(DN 15 to 65 /
6.0 MHz
½ to 2½")
• IP 67 / NEMA 4X
Clamp-on version
• IP 68 / NEMA 6P
DN 15 to 65 (½ to 2½"), –40 to +130 °C (–4 to +266 °F),
6.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
Sensor W
DN 50 to 300 (2 to 12"), –20 to +80 °C (–4 to +176 °F),
(DN 50 to 4000 /
2.0 MHz
2 to 160")
• IP 67 / NEMA 4X
Clamp-on version
• IP 68 / NEMA 6P
DN 100 to 4000 (4 to 160"), –20 to +80 °C (–4 to +176 °F),
1.0 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
DN 100 to 4000 (4 to 160"), 0 to +130 °C (+32 to +266 °F),
1.0 MHz
• IP 67 / NEMA 4X
DN 50 to 300 (2 to 12"), 0 to +130 °C (+32 to +266 °F),
2.0 MHz
• IP 67 / NEMA 4X
DN 100 to 4000 (4 to 160"), –20 to +80 °C ( –4 to +176 °F),
0.5 MHz
• IP 67 / NEMA 4X
• IP 68 / NEMA 6P
Sensor W
DN 200 to 4000 (8 to 160"), –40 to +80 °C (–40 to +176 °F)
(DN 200 to 4000
/ 8 to 160")
Insertion version
Proline Prosonic Flow 93 FOUNDATION Fieldbus
Order code
Single-channel version:
93XXX - XX1XX********
Two-channel version:
93XXX - XX2XX********
DK9UI - **
DK9PS - 1*
DK9PS - 2*
DK9PS - B*
DK9PS - F*
DK9PS - A*
DK9PS - E*
DK9WS -1
DK9WS -3
DK9WS -2
DK9WS -4
DK9WS - B*
DK9WS - N*
DK9WS - A*
DK9WS - M*
DK9WS - P*
DK9WS - S*
DK9WS - R*
DK9WS - T*
DK9WS - K*
Endress+Hauser