Proline Prosonic Flow 93 FOUNDATION Fieldbus
Endress+Hauser
1
6
5
7.1
7.3
7.2
3
Fig. 84:
Wall-mount housing: removing and installing electronics boards
1
Housing cover
2
Electronics module
3
Ribbon cable (display module)
4
Screws of electronics compartment cover
5
Aperture for installing/removing boards
6
Power unit board
7
Amplifier board
7.1
Signal cable (sensor)
7.2
Excitation current cable (sensor)
7.3
T-DAT (transmitter data storage device)
8
I/O board (FOUNDATION Fieldbus type)
2
7
5
5
Troubleshooting
3
8
4
A0014846
111