Installation
"
56
3.14.2

Panel mounting

Prepare the opening in the panel  å 65.
1.
2.
Slide the housing into the panel cutout from the front.
3.
Screw the retainers onto the wall-mount housing.
4.
Screw the threaded rods into the retainers and tighten until the housing is solidly seated on the
panel wall. Tighten the counter nuts. No further support is necessary.
mm (inch)
Fig. 65:
Panel mounting (wall-mount housing)
3.14.3

Pipe mounting

The assembly should be performed by following the instructions on  ä 56.
Caution!
If a warm pipe is used for installation, make sure that the housing temperature does not exceed the
max. permitted value of +60 °C (+140 °F).
Ø 20...70
(Ø 0.79...2.75)
mm (inch)
Fig. 66:
Pipe mounting (wall-mount housing)
Proline Prosonic Flow 93 FOUNDATION Fieldbus
+0.5 (+0.019)
–0.5 (–0.019)
210 (8.27)
245 (9.65)
~110 (~4.33)
155 (
~ 6.1)
~
+0.5 (+0.019)
–0.5 (–0.019)
A0001131
A0001132ae