Identification
8
2.1.2
Nameplate of the sensor
II2G EEx ib IIC T6-T1
II2D Ex ibD 21 T6-T1
8
DMT 01 ATEX E 064 X
IECEx BVS 06.0... X
7
Tamb/Tumg:-40°C..+60°C
4153 Reinach
Switzerland
PROSONIC FLOW P
Order Code:
1
Ser.No.:
2
Type:
DN100 - DN4000
3
4
-40°C (-40°F) ... +80°C (+175°F)
5
Fig. 2:
Nameplate specifications for the "Prosonic Flow P" sensor (example)
1
Order code/serial number: See the specifications on the order confirmation for the meanings of the individual
letters and digits.
2
Sensor type
3
Range of nominal diameter: DN 100 to 4000 (4 to 160")
4
Max. fluid temperature range: –40 to +80 °C (–40 to +175 °F)
5
Reserved for information on special products
6
Degree of protection
7
Permitted ambient temperature range
8
Data on explosion protection
Refer to the specific additional Ex documentation for detailed information.
Please do not hesitate to contact your Endress+Hauser sales office if you have any questions.
9
Please refer to operating instructions / documentation
Proline Prosonic Flow 93 FOUNDATION Fieldbus
6
IP68
0044
NEMA
FM
N12895
TYPE 6P
APPROVED
Intrinsically safe for CL.I, GP.ABCD
CL.II, GP.EFG, CL.III
Dust-Ignitionproof for
CL.II, GP. EFG, CL.III
For Installation refer to
control dwg. of transmitter
XXXXX-XXXXXXXXXXXX
12345678901 RY
P-CL-1F-L-B
OPEN
XA059D/
i
2007
06/../....
CH 1
CLOSE
Endress+Hauser
9
A0001158
Need help?
Do you have a question about the Proline Prosonic Flow 93 and is the answer not in the manual?
Questions and answers