Installing A High-Performance Fan - HPE ProLiant DL360 User Manual

Hide thumbs Also See for ProLiant DL360:
Table of Contents

Advertisement

7.
Install the access panel (Installing the access panel on page 25).
8.
Install the server in the rack.
9.
Connect each power cord to the server.
10. Connect each power cord to the power source.
11. Power up the server (Powering up the server on page 24).
Use the BIOS/Platform Configuration (RBSU) in the UEFI System Utilities to configure the memory mode.
For more information about LEDs and troubleshooting failed DIMMs, see Systems Insight Display
combined LED descriptions on page 12.

Installing a high-performance fan

This kit is available to meet some extended ambient operating temperatures above 35 degrees Celsius. For
more information about the qualifications for extended ambient configurations, see the Hewlett Packard
Enterprise website.
The high-performance fans are used for 8-SFF and 10 SFF drive configurations. They are also required for
the 10 SFF SAS/SATA/NVMe Combo backplane option and for ASHRAE compliant configurations. For more
information on ASHRAE compliant configurations, see the Hewlett Packard Enterprise website.
Prerequisites
Before installing this option, be sure you have the following:
The components included with the hardware option kit
Procedure
1.
Observe the following alert:
IMPORTANT:
After removing a high-performance (dual-rotor) fan, install or replace the fan within 60 seconds.
Otherwise, the server will shut down gracefully.
2.
Power down the server (Power down the server on page 24).
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Do one of the following:
44
Installing a high-performance fan