Installing A 2 Sff Hpe Smart Carrier M.2 (Scm) Drive Cage - HPE ProLiant DL360 User Manual

Hide thumbs Also See for ProLiant DL360:
Table of Contents

Advertisement

18. Power up the server (Powering up the server on page 24).
19. Install drives.

Installing a 2 SFF HPE Smart Carrier M.2 (SCM) drive cage

Prerequisites
Hewlett Packard Enterprise recommends installing the P816i-a controller to support more than eight SAS/
SATA drives. Additional controller options are available. For more information, see the HPE DL360 Gen10
Server cabling matrix on the Hewlett Packard Enterprise website (http://www.hpe.com/info/
CablingMatrixGen10).
Before installing this option, be sure you that have the following:
The components included with the hardware option kit
T-10 Torx screwdriver
Additional cables, as needed. For more information, see SFF cables on page 114.
2 SFF SAS/SATA drives, 4 uFF M.2 drives, or blanks
For more information, contact a Hewlett Packard Enterprise authorized reseller.
Procedure
1.
Back up all server data.
2.
Power down the server (Power down the server on page 24).
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Do one of the following:
a. Extend the server from the rack (Extend the server from the rack on page 24).
b. Remove the server from the rack (Remove the server from the rack on page 25).
5.
Remove the access panel (Remove the access panel on page 25).
6.
Remove the universal media bay blank.
7.
Install the drive cage.
58
Installing a 2 SFF HPE Smart Carrier M.2 (SCM) drive cage

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents