Installing High-Performance Fans - HPE ProLiant DL388 Gen10 User Manual

Hide thumbs Also See for ProLiant DL388 Gen10:
Table of Contents

Advertisement

Configuration
1 processor
1 processor 24-SFF
or 12-LFF
configuration with
high-performance
fans
2 processors
For a single-processor configuration, excluding 24-SFF and 12-LFF configurations, four fans and two blanks
are required in specific fan bays for redundancy. A fan failure or missing fan causes a loss of redundancy. A
second fan failure or missing fan causes an orderly shutdown of the server.
For a dual-processor configuration or single-processor 24-SFF or 12-LFF configurations, six fans are required
for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan
causes an orderly shutdown of the server.
High-performance fans might be necessary in 24-SFF and 12-LFF configurations for the following
installations:
Optional GPU riser installations
ASHRAE compliant configurations
For more information, see the Hewlett Packard Enterprise website.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following temperature-
related scenarios:
At POST and in the OS, iLO performs an orderly shutdown if a cautionary temperature level is detected. If
the server hardware detects a critical temperature level before an orderly shutdown occurs, the server
performs an immediate shutdown.
When the Thermal Shutdown feature is disabled in the BIOS/Platform Configuration (RBSU), iLO does not
perform an orderly shutdown when a cautionary temperature level is detected. Disabling this feature does
not disable the server hardware from performing an immediate shutdown when a critical temperature level
is detected.
CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is
disabled in the BIOS/Platform Configuration (RBSU).

Installing high-performance fans

CAUTION: Caution: To prevent damage server, ensure that all DIMM latches are closed and locked
before installing the fans.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can lead to
thermal damage.
Fan bay 1
Fan bay 2
Fan blank
Fan blank
Fan
Fan
Fan
Fan
Fan bay 3
Fan bay 4
Fan
Fan
Fan
Fan
Fan
Fan
Hardware options installation
Fan bay 5
Fan bay 6
Fan
Fan
Fan
Fan
Fan
Fan