Task
Display information about MPLS TE tunnel
interfaces.
Display information about PCEs discovered by
OSPF.
Display link and node information in an OSPF
TEDB.
Display network information in an OSPF TEDB.
Display OSPF tunnel interface information.
Clear PCC and PCE statistics.

MPLS TE configuration examples

Establishing an MPLS TE tunnel over a static CRLSP

Network requirements
Switch A, Switch B, and Switch C run IS-IS.
Establish an MPLS TE tunnel over a static CRLSP from Switch A to Switch C to transmit data
between the two IP networks.
The MPLS TE tunnel requires a bandwidth of 2000 kbps. The maximum bandwidth of the link that the
tunnel traverses is 10000 kbps. The maximum reservable bandwidth of the link is 5000 kbps.
Figure 32 Network diagram
IP network
Configuration procedure
1.
Configure IP addresses and masks for interfaces. (Details not shown.)
2.
Configure IS-IS to advertise interface addresses, including the loopback interface address:
# Configure Switch A.
<SwitchA> system-view
Vlan-int1
2.1.1.2/24
Vlan-int1
Vlan-int10
2.1.1.1/24
100.1.1.1/24
Switch A
Loop0
1.1.1.1/32
Command
display mpls te tunnel-interface [ tunnel number ]
display ospf [ process-id ] [ area area-id ] mpls te pce
[ originate-router advertising-router-id | self-originate ]
display ospf [ process-id ] [ area area-id ] mpls te
advertisement [ originate-router advertising-router-id |
self-originate ]
display ospf [ process-id ] [ area area-id ] mpls te
network [ originate-router advertising-router-id |
self-originate ]
display ospf [ process-id ] [ area area-id ] mpls te
tunnel
reset mpls te pce statistics [ ip-address ]
Loop0
2.2.2.2/32
Vlan-int2
3.2.1.1/24
Switch B
Vlan-int2
3.2.1.2/24
Switch C
Loop0
3.3.3.3/32
104
Vlan-int10
100.1.2.1/24
IP network