Establishing an MPLS TE tunnel with RSVP-TE

Network requirements
Switch A, Switch B, Switch C, and Switch D run IS-IS and all of them are Level-2 switches.
Use RSVP-TE to establish an MPLS TE tunnel from Switch A to Switch D to transmit data between
the two IP networks. The MPLS TE tunnel requires a bandwidth of 2000 kbps.
The maximum bandwidth of the link that the tunnel traverses is 10000 kbps and the maximum
reservable bandwidth of the link is 5000 kbps.
Figure 33 Network diagram
IP network
Vlan-int10
Switch A
Loop0
Table 3 Interface and IP address assignment
Device
Switch A
Switch B
Configuration procedure
1.
Configure IP addresses and masks for interfaces. (Details not shown.)
2.
Configure IS-IS to advertise interface addresses, including the loopback interface address:
# Configure Switch A.
<SwitchA> system-view
[SwitchA] isis 1
[SwitchA-isis-1] network-entity 00.0005.0000.0000.0001.00
[SwitchA-isis-1] quit
[SwitchA] interface vlan-interface 1
[SwitchA-Vlan-interface1] isis enable 1
Vlan-int1
Loop0
Vlan-int1
Vlan-int2
Switch B
Interface
IP address
Loop0
1.1.1.9/32
Vlan-int1
10.1.1.1/24
Vlan-int10
100.1.1.1/24
Loop0
2.2.2.9/32
Vlan-int1
10.1.1.2/24
Vlan-int2
20.1.1.1/24
Vlan-int3
Loop0
Vlan-int3
Vlan-int2
Switch C
Device
Interface
Switch D
Loop0
Vlan-int3
Vlan-int10
Switch C
Loop0
Vlan-int3
Vlan-int2
109
IP network
Vlan-int10
Switch D
Loop0
IP address
4.4.4.9/32
30.1.1.2/24
100.1.2.1/24
3.3.3.9/32
30.1.1.1/24
20.1.1.2/24