Connecting To Sgdv-E5A Servopack; Connecting To Sgdv-E5A Servopack (Command Option Attachable Type) - YASKAWA SGLGW User Manual

E-v series ac servo drives
Hide thumbs Also See for SGLGW:
Table of Contents

Advertisement

3 Wiring and Connection
3.2.4 Connecting to SGDV-E5A SERVOPACK (Command Option Attachable Type)
3.2.4
Connecting to SGDV-
Option Attachable Type)
(1)
SGDV-FE5A
Power supply
Single-phase 100 VAC
Molded-case
circuit breaker
(MCCB)
Protects the power
supply line by
shutting the circuit
OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor*
Linear servomotor
main circuit cable


3-16
R
T
SGDV-
SERVOPACK
1
Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-
necting Regenerative Resistors.
For connection to the command option module, refer to the user's manual of the corre-
sponding option module.
www.dadehpardazan.ir 88594014-15

E5A SERVOPACK (Command
FE5A
Option module*
Connection cable
for digital operator
Connection cable
for personal computer
I/O signal cable
Cable for connecting a
serial converter unit
Serial converter unit
Cable for connecting a
linear scale
Linear scale
(Not included)
Digital
operator
2
Personal
computer
External LED indicator,
external device, etc.
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
Cable for connecting a
hall sensor
Linear servomotor
with core

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglcSgltwSglfw

Table of Contents