(1)
Heidenhain Linear Scale
Reverse direction
Sensor head
(2)
Renishaw Linear Scale
Forward direction
Signal cable
(3)
Mitutoyo Linear Scale
 ST781A, ST783A, ST788A, and ST789A
Reverse direction
Sensor head
 ST782A and ST784A
Reverse direction
www.dadehpardazan.ir 88594014-15
2.3 Linear Scale Installation and Adjustment
Forward direction
LIDA 48
HEIDENHAIN
Signal cable
Reverse direction
RENISHAW
RGH22
Sensor head
Forward direction
Mitsutoyo
Signal cable
Signal cable
Forward direction
Mitsutoyo
Sensor head
When installed as shown in the diagram
on the left, operation is performed in the
forward direction when the sensor head
is moved to the right.
When installed as shown in the diagram
on the left, operation is performed in the
forward direction when the sensor head
is moved to the left.
When installed as shown in the diagram
on the left, operation is performed in the
forward direction when the sensor head
is moved to the left.
When installed as shown in the diagram
on the left, operation is performed in the
forward direction when the sensor head
is moved to the right.
2