2 Installation
2.2.4 SGLC Linear Servomotors (Cylinder Type)
4.
5.
6.
2-24
After mounting the movable table provided by the customer on the linear
guide, transfer the movable table onto the moving coil and secure them
with bolts.
• Carefully lay wiring so that no cables are caught, and fix them to the movable
table.
• For the recommended tightening torque of the bolts for fixing the moving coil,
refer to Table 2.2 Moving Coil and Recommended Tightening Torque.
Table 2.2 Moving Coil and Recommended Tightening Torque
Moving Coil
Model
SGLCW-
D16
D20
D25
D32
Note: Use hexagon socket head cap screws made of austenite stainless steel 
(equivalent to the strength class A2-70.)
Remove the part made of resin between the moving coil and the
magnetic way. Be careful not to get your fingers or other objects caught
between the moving coil and the magnetic way because a strong
magnetic attraction is generated between them.
Perform several full strokes with the movable table, and make sure that
the table may not come into contact with the magnetic way. (The size of
the gaps is not specified.)
www.dadehpardazan.ir 88594014-15
Nominal Diameter
of Bolts
M3
M4
M5
M6
Tightening torque
(Ncm)
100
220
450
760