YASKAWA SGLGW User Manual page 49

E-v series ac servo drives
Hide thumbs Also See for SGLGW:
Table of Contents

Advertisement

2 Installation
2.2.4 SGLC Linear Servomotors (Cylinder Type)
 Leakage Flux of the Magnetic Way
The following table shows the leakage flux of the magnetic way.
Moving Coil Model
D16
D20
D25
D32
2-26
Diameter of
Magnetic Way
SGLCW-
A
www.dadehpardazan.ir 88594014-15
Table 2.4 Leakage Flux
Places Where the Leakage Flux is 10
Distance from the
Surface of the
D (mm)
Magnetic Way
A (mm)
16
80 or less
20
25
32
B
D
Magnetic way
Gausses or More
Diameter
B (mm)
176 or less
100
120
140
220
265
312

Advertisement