2 Installation
2.5.2 SGDV-15 (M-II Model)
 Three-phase 400 V, SGDV-260D15A
Power supply:
Single-phase
200 VAC
Power supply:
Three-phase
400 VAC
PE
MECHATROLINK-II
controller
Symbol



2-52
5
Noise
filter*
Surge
absorber
6
Surge
absorber
Regenerative
resistor cable
8
I/O signal cable
Cable for safety unit
Linear servomotor main circuit cable
Linear scale connection cables
Control power cable
Main circuit cable
Regenerative resistor unit cable
MECHATROLINK-II communication cable Shield cable
Products that have received CE marking are recommended for the 24 VDC power supply.
Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)
For more information on this filter, refer to
42)
www.dadehpardazan.ir 88594014-15
2
SERVOPACK
Control
power
24 V, 0 V
supply
1
24 VDC*
Noise
L1, L2, L3
filter*
3
7
B1, B2
CN6A, CN6B
CN1
Clamp
1
Safety unit
Host
controller
Cable Name
-V Series Product Catalog. (KAEP S800000
Shield box
U, V, W
3
CN2
4
CN8
Clamp
2
Specification
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Non-shield cable
Linear
servomotor
Linear
scale
PE

Advertisement