YASKAWA SGLGW User Manual page 98

E-v series ac servo drives
Hide thumbs Also See for SGLGW:
Table of Contents

Advertisement

(2)
SGDV-A25
 Using a Three-phase, 200-V Power Supply
Power supply
Single-phase 200 VAC
R S T
Molded-case
circuit breaker
(MCCB)
Protcts the power supply
line by shutting the
circuit OFF when
overcurrent is detected.
Noise filter
Used to eliminate
external noise from
the power line.
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor*
Linear servomotor
main circuit cable
 Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-
necting Regenerative Resistors.
www.dadehpardazan.ir 88594014-15
SGDV-
A25
SERVOPACK
Cable for connecting a
serial converter unit
Serial converter unit
Cable for connecting a
linear scale
Linear scale
(Not included)
3.2 System Configuration Diagram
Connect to the
MECHATROLINK-III
Connection cable
for digital operator
Connection cable
for personal computer
I/O signal cable
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Linear servomotor
with core
Digital
operator
Personal
computer
Host controller
Safety function
devices
Cable for connecting a
hall sensor
3-13
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglcSgltwSglfw

Table of Contents