(2)
SGDV-AE5A
 Using a Three-phase, 200-V Power Supply
Power supply
Three-phase 200 VAC
R S T
Molded-case
circuit breaker
(MCCB)
Protects the power supply
line by shutting the
circuit OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
Magnetic contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Regenerative
resistor*
1
Linear servomotor
main circuit cable

Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-
necting Regenerative Resistors.

For connection to the command option module, refer to the user's manual of the corre-
sponding option module.
www.dadehpardazan.ir 88594014-15
SGDV-
AE5A
SERVOPACK
Connection cable
for digital operator
Connection cable
for personal computer
Cable for connecting a
serial converter unit
Serial converter unit
Cable for connecting a
linear scale
Linear scale
(Not included)
3.2 System Configuration Diagram
Option module*
2
I/O signal cable
External LED indicator,
external device, etc.
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Cable for connecting a
hall sensor
Linear servomotor
with core
Digital
operator
Personal
computer
Safety function
devices
3
3-17