5 Trial Operation (Checking Linear Servomotor Operation)
5.3.1 Setting and Checking the Linear Scale Pitch
• When the motor parameters have not yet been written
Proce-
Display after operation
dure
1
2
3
Connected servomotor model
4
• When Using SigmaWin+
Note: The linear scale pitch can be checked by using the monitor mode parameters Un084
Example
When Un084 = 800, and Un085 = 6
Linear scale pitch = Un084 10
5-8
SERVOPACK model
Connected linear scale model
Start SigmaWin+. Click Monitor in the main menu and then click Product
Information.
(Linear Scale Pitch) and Un085 (Linear Scale Pitch Index).
www.dadehpardazan.ir 88594014-15
Keys
[pm] = 800  10
Un085
6
Operation
Press the
Key to view the
main menu of Utility Function.
Press the
or
select Fn01E.
Press the
Key.
The SERVOPACK model being
used will be displayed.
Press the
Key again.
The connected servomotor model
will be displayed.
Note: If the linear scale data is not
saved in the SERVO-
PACK, nothing will be dis-
played under Motor.
Press the
Key again.
The linear scale model will be
displayed.
Note: If the linear scale data is not
saved in the SERVO-
PACK, nothing will be dis-
played under Encoder.
[pm] = 800 [m]
Key to

Advertisement

Table of Contents
loading

This manual is also suitable for:

SglcSgltwSglfw

Table of Contents