(3)
SGDV-D25A
Power supply
Three-phase 400 VAC
R S T
Molded-case
circuit breaker
MCCB)
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is
detected.
Noise filter
Used to eliminate
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
∗
24 VDC
1
power supply
Regenerative
resistor*
2
Linear servomotor
main circuit cable
Use a 24 VDC power supply with double insulation or reinforced insulation. (The power
supply is not included)
Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-
necting Regenerative Resistors.
www.dadehpardazan.ir 88594014-15
SGDV-
D25A
SERVOPACK
Cable for connecting a
serial converter unit
Cable for connecting a
linear scale
Linear scale
(Not included)
3.2 System Configuration Diagram
Connect to the
MECHATROLINK-III
Personal
computer
Connection cable
for digital operator
Connection cable
for personal computer
Host controller
I/O signal cable
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Serial converter unit
Cable for connecting a
hall sensor
Linear servomotor
with core
Digital
operator
Safety function
devices
3