2.5.1 SGDV-05 (Analog Pulse Model)
 Three-phase 400 V, SGDV-260D05A
Power supply:
Single-phase
200 VAC
Power supply:
Three-phase
400 VAC
PE
Symbol



2-44
5
Noise
filter*
Surge
absorber
6
Surge
absorber
Regenerative
resistor unit
I/O signal cable
Cable for safety unit
Linear servomotor main circuit cable
Linear scale connection cables
Control power cable
Main circuit cable
Regenerative resistor unit cable
Products that have received CE marking are recommended for the 24 VDC power supply.
Install the following noise filter on the power line between the single-phase 200 V power
supply and the 24 VDC power supply.
Model number: FN2070-6/07 (SCHAFFNER)
For more information on this filter, refer to
42)
www.dadehpardazan.ir 88594014-15
2
SERVOPACK
Control
power
24 V, 0 V
supply
24 VDC*
1
Noise
L1, L2, L3
3
filter*
B1, B2
7
CN1
cable
Clamp
1
Host
Safety unit
controller
Cable Name
-V Series Product Catalog. (KAEP S800000
Shield box
U, V, W
3
CN2
4
CN8
Clamp
2
Specification
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Shield cable
Non-shield cable
Linear
servomotor
Linear
scale
PE