3 Wiring and Connection
3.3.2 When Using a Standard Power Supply Input (Single-phase 100 V, Three-phase 200 V, or
Three-phase 400 V)
 Three-phase 400 V, SGDV-D 
(SGDV-1R9D, 3R5D, 5R4D, 8R4D, 120D, 170D)
Note: For M-II model, M-III model, and command option attachable type SERVOPACKs, the
 Three-phase 400 V, SGDV-D (SGDV-260D)
Note: For M-II model, M-III model, and command option attachable type SERVOPACKs, the
3-26
R S T
1QF
3SA
1FLT
DC power
supply (24 V)
Servo power
Servo power
supply ON
1KM
1KM
1Ry
1QF
: Molded-case circuit breaker
1FLT
: Noise filter
1KM
: Magnetic contactor (for control power supply)
2KM
: Magnetic contactor (for main power supply)
pin number of ALM+ terminal is CN1-3, and that of ALMterminal is CN1-4.
R S T
1QF
3SA
1FLT
2KM
DC power
supply (24 V)
1Ry
Servo power
Servo power
supply ON
supply OFF
1KM
1KM
1Ry
1QF
: Molded-case circuit breaker
1FLT
: Noise filter
1KM
: Magnetic contactor (for control power supply)
2KM
: Magnetic contactor (for main power supply)
pin number of ALM+ terminal is CN1-3, and that of ALMterminal is CN1-4.
www.dadehpardazan.ir 88594014-15
SERVOPACK
SGDV-
2KM
L1
L2
L3
1KM
+
24 V
0 V
(For servo
B1/
alarm display)
1Ry
B2
B3
1PL
supply OFF
1KM
1SA
2KM
2SA
SERVOPACK
SGDV-
L1
L2
L3
1KM
+
24 V
0 V
(For servo
B1/
alarm display)
B2
1PL
1KM
1SA
Regenerative
2KM
resister unit
2SA
D
U
V
M
W
ENC
+24 V
CN1
1Ry
31
+
ALM
1
1D
32
0 V
ALM
2
1Ry
: Relay
1PL
: Indicator lamp
1SA
: Surge absorber
2SA
: Surge absorber
3SA
: Surge absorber
1D
: Flywheel diode
D
U
V
M
W
ENC
+24 V
CN1
1Ry
ALM
+
31
1
1D
ALM
32
0 V
2
1Ry
: Relay
1PL
: Indicator lamp
1SA
: Surge absorber
2SA
: Surge absorber
3SA
: Surge absorber
1D
: Flywheel diode