FUTABA FX-36 Instruction Manual page 91

18-channel digital proportional r/c system
Hide thumbs Also See for FX-36:
Table of Contents

Advertisement

Sensor
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
to the S.BUS2 port of the transmitter.
When using 2 or more of the same kind of
sensor, they must be registered here.
Tap the [Sensor] button in the Linkage menu
to call the setup screen shown below.
Slot Number
Sensor ID : Multiple usage of sensors
of the same type requires an ID
be input. Tapping this will allow
for manual input, but see the next
page about how to perform auto-
registration via sensor registration.
As shown in the table below, an altimeter re uires 3 contiguous slots and a GPS sensor
re uires 8 contiguous slots. The GPS (SBS-01/02G) start slots are 8, 16, and 24.
< Assignable slot >
Sensor
number of slots
TEMP (SBS-01T/TE)
RPM (SBS01RM/RO/RB)
Voltage (SBS-01V)
Altitude (SBS-01/02A)
Current (SBS-01C)
S.BUS Servo sennsor
(SBS-01S)
GPS(SBS-01/02G)
TEMP125-F1713
VARIO-F1712
VARIO-F1672
CURR-F1678
GPS-F1675
Kontronik ESC
Castle TL0
JetCat V10
PowerBox
Various telemetry sensors setting
Registered sensor
Tap the slot to display
sensors which can be used
for the start slot. Tap to
register the sensor.
*Altimeter, GPS, and other sensors that display a large amount of data require multiple slots.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
The required
1 slot
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
6 slots
8 slots
1 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 ,
2 slots
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 ,
3 slots
8 slots
8 slots
8 slots
1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 5 , 1 6 , 1 7 ,
14 slots
16 slots
Servos are classified by CH, but sensors are
classified in units called "slot". There are slots from
No. 1 to No. 31.
Altitude sensors, GPS sensors and other data
sensor units may use multiple slots.
When using a sensor which uses two or more slots,
the required number of slots is automatically assigned
by setting up a start slot.
When 2 or more of the same kind of sensor are used,
the sensors themselves must allocate unused slots and
memorize that slot.
The number which can be used as a start slot
1-31
1-31
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
1 , 2 , 8 , 9 , 1 0 , 1 6 , 1 7 , 1 8 ,
2 4 , 2 5 , 2 6
8 , 1 6 , 2 4
1-31
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
2 0 , 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9
8 , 1 6 , 2 4
8 , 1 6 , 2 4
8 , 1 6 , 2 4
1 8
8 , 1 6
[What is a slot?]
This is what displays when no
s e n s o r i s r e g i s t e r e d i n a s l o t .
Tapping the slot and selecting
"-----------" will erase whatever was
registered there, freeing up the
slot.
< Linkage menu >
Selling area
Global
Europe
91

Advertisement

Table of Contents