Telemetry: Voltage [Battery]
In this screen, the battery voltage is displayed.
In order to use this function, it is necessary to
connect External voltage connector of R7008SB ⇔
SBS-01V ⇔ Battery
SBS-01V measures two batteries. The power
battery connected to two lines is displayed on EXT-
VOLT. The battery for receivers connected to 3P
lines is displayed here.
Tap the [Voltage] button in the Telemetry screen
to call the setup screen shown below.
Return to
Linkage menu
Max. and min. values
s i n c e t h e p o w e r
was turned ON will
display.
↓ The "down" arrow
will indicate that an
alarm will sound when
the voltage drops to
below the setting.
Alarm is chosen from
Buzzer, Voice, and
Inhibit.
Allows Speech to be
turned ON or OFF.
Alarm set
1. Tap Alarm and choose from Bu
Voice, and Inhibit.
2. Choose "Inhibit" for Vibrator if not using
the vibrator alarm. If using vibrator,
choose one of the three types.
3. Tap to the Limit [4.0V] item .
4. Adjust the rate using the "
"
" buttons.
Initial value: 4.0V
Adjustment range: 0.0V~100.0V
*When the screen is tapped for one second, the rate is
reset to the initial value.
5. To terminate the input and return to the
original state, push the H/E button.
*Refer to the manual of SBS-01V for the details of
wiring.
Displaying data from the receiver battery voltage
*SBS-01V must be installed in the aircraft.
In this screen, the battery voltage of a receiver is
displayed.
If it becomes higher or lower than the settin, an
alarm and/or vibration will alert you.
*It cannot be used in FASST mode and S-FHSS mode.
*Only receiver voltage and EXT voltage can be used in
FASSTest12CH mode.
*The FASSTest18CH /T-FHSS mode can use all the telemetry
functions.
Vibrator choices are
type1-3, and Inhibit.
< Two examples of wiring are shown >
Drive battery 1
er,
(EXT Battery)
Drive battery 2
(EXT Battery)
Receiver battery
" " " " "
Two drive batteries and power supplies for servos are measured (R7008SB use)
Drive battery 1
(EXT Battery)
Drive battery 2
(EXT Battery)
Power supplies
for servos
S.BUS2
servos
Battery voltage
Two drive batteries are measured (R7008SB use)
EXT Line
●Battery voltage measurement for receivers [R7008SB use]
●The drive battery 1 is measured in an EXT port [R7008SB use]
●The drive battery 2 is measured in an EXT line [SBS-01V use]
*SBS-01V measures two voltage. One corresponds to high voltages, such as a drive battery,
with an EXT line. Another is a normal line and is measurement of the battery for receivers of a
line connected to 3P connector, or the battery for servos.
EXT Line
Normal Line
Receiver battery
●Battery voltage measurement for receivers [R7008SB use]
●The drive battery 1 is measured in an EXT port [R7008SB use]
●The drive battery 2 is measured in an EXT line [SBS-01V use]
●The voltage for servos is measured in a power supply line [SBS-01V use]
< Linkage menu >
Sets the voltage on
w h i c h t h e a l a r m
operates.
Normal Line