Minimum permissible data frame length: FLmin = 11 × FL −
Therefore, the maximum receivable baud rate at the transmission source is as follows.
BRmax = (FLmin/11)
Similarly, the maximum permissible data frame length can be calculated as follows.
10
k + 2
× FLmax = 11 × FL −
2 × k
11
21k – 2
FL × 11
FLmax =
20k
Therefore, the minimum receivable baud rate at the transmission source is as follows.
BRmin = (FLmax/11)
The permissible baud rate error between UART6 and the transmission source can be calculated from the above
minimum and maximum baud rate expressions, as follows.
Table 11-5. Maximum/Minimum Permissible Baud Rate Error
Division Ratio (k)
Maximum Permissible Baud Rate Error
8
20
50
100
255
Remarks 1. The permissible error of reception depends on the number of bits in one frame, input clock
frequency, and division ratio (k). The higher the input clock frequency and the higher the division
ratio (k), the higher the permissible error.
2. k: Set value of BRGC6
CHAPTER 11 SERIAL INTERFACE UART6
22k
1
=
Brate
21k + 2
21k − 2
× FL =
FL
2 × k
20k
1
=
Brate
21k − 2
+3.53%
+4.26%
+4.56%
+4.66%
+4.72%
User's Manual U17446EJ3V1UD
k − 2
21k + 2
× FL =
FL
2k
2k
Minimum Permissible Baud Rate Error
−3.61%
−4.31%
−4.58%
−4.67%
−4.73%