Mitsubishi MR-JE-10A Instruction Manual page 63

Servo amplifiers
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(b) Output device
Device
Symbol
Malfunction
ALM
Ready
RD
In-position
INP
Speed reached
SA
Limiting speed
VLC
Limiting torque
TLC
Zero speed
ZSP
detection
Electromagnetic
MBR
brake interlock
Warning
WNG
Connector
pin No.
CN1-48
When an alarm occurs, ALM will turn off.
When an alarm does not occur, ALM will turn on after 2.5 s to 3.5 s after
power-on.
When [Pr. PD34] is "_ _ 1 _", an alarming or warning will turn off ALM.
CN1-49
Enabling servo-on to make the servo amplifier ready to operate will turn on
RD.
CN1-24
When the number of droop pulses is in the preset in-position range, INP
will turn on. The in-position range can be changed using [Pr. PA10]. When
the in-position range is increased, INP may be on during low-speed
rotation.
INP turns on when servo-on turns on.
When the servo motor speed reaches the following range, SA will turn on.
Set speed ± ((Set speed × 0.05) + 20) r/min
When the preset speed is 20 r/min or less, SA always turns on.
SA does not turn on even when the SON (Servo-on) is turned off or the
servo motor speed by the external force reaches the preset speed while
both ST1 (Forward rotation start) and ST2 (reverse rotation start) are off.
VLC turns on when speed reaches a value limited with any of [Pr. PC05
Internal speed limit 1] to [Pr. PC11 Internal speed limit 7] or VLA (Analog
speed limit).
This turns off when SON (Servo-on) turns off.
TLC turns on when a generated torque reaches a value set with any of [Pr.
PA11 Forward torque limit], [Pr. PA12 Reverse torque limit], or TLA
(Analog torque limit).
CN1-23
ZSP turns on when the servo motor speed is zero speed (50r/min) or less.
Zero speed can be changed with [Pr. PC17].
OFF level
Forward
70 r/min
rotation
ON level
direction
50 r/min
Servo motor
0 r/min
speed
ON level
Reverse
-50 r/min
rotation
OFF level
direction
-70 r/min
ON
ZSP
(Zero speed
OFF
detection)
ZSP will turn on when the servo motor is decelerated to 50 r/min (at 1)),
and will turn off when the servo motor is accelerated to 70 r/min again (at
2)).
ZSP will turn on when the servo motor is decelerated again to 50 r/min (at
3)), and will turn off when the servo motor speed has reached -70 r/min (at
4)).
The range from the point when the servo motor speed has reached on
level, and ZSP turns on, to the point when it is accelerated again and has
reached off level is called hysteresis width.
Hysteresis width is 20 r/min for this servo amplifier.
When using the device, set operation delay time of the electromagnetic
brake in [Pr. PC16].
When a servo-off status or alarm occurs, MBR will turn off.
When warning has occurred, WNG turns on. When a warning is not
occurring, turning on the power will turn off WNG after 2.5 s to 3.5 s.
Function and application
1)
3)
2)
4)
3 - 28
Control
I/O
mode
division
P
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
20 r/min
(Hysteresis width)
[Pr. PC17]
[Pr. PC17]
20 r/min
(Hysteresis width)
DO-1
DO-1
S
T