Mitsubishi MR-JE-10A Instruction Manual page 54

Servo amplifiers
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(2) Cable connection procedure
(a) Fabrication on cable insulator
Refer to table 3.1 and 3.2 for stripped length of cable insulator. The appropriate stripped length of
cables depends on their type, etc. Set the length considering their status.
Twist strands lightly and straighten them as follows.
You can also use a ferrule to connect with the connectors. When you use a ferrule, use the following
ferrules and crimp terminal.
Servo amplifier
MR-JE-10A to
MR-JE-100A
MR-JE-200A to
MR-JE-300A
(b) Inserting wire
Insert the open tool as follows and push down it to open the spring. While the open tool is pushed
down, insert the stripped wire into the wire insertion hole. Check the insertion depth so that the wire
insulator does not get caught by the spring.
Release the open tool to fix the wire. Pull the wire lightly to confirm that the wire is surely connected.
The following shows a connection example of the CNP2 connector for 2 kW and 3 kW.
Insulator
Stripped length
Loose and bent strands
Ferrule model (Phoenix Contact)
Wire size
For one
AWG 16
AI1.5-10BK
AWG 14
AI2.5-10BU
AWG 16
AI1.5-10BK
AWG 14
AI2.5-10BU
AWG 12
AI4-10GY
3 - 19
Core
Twist and straighten
the strands.
For two
AI-TWIN2×1.5-10BK
AI-TWIN2×1.5-10BK
AI-TWIN2×2.5-10BU
1) Push down the open tool.
3) Release the open tool to fix the wire.
2) Insert the wire.
Crimp terminal
(Phoenix Contact)
CRIMPFOX-ZA3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents