Wiring Cnp1 And Cnp2 - Mitsubishi MR-JE-10A Instruction Manual

Servo amplifiers
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.3.3 Wiring CNP1 and CNP2

To wire to CNP1 and CNP2, use servo amplifier power connectors packed with the amplifier or optional
connectors (refer to section 11.1.1).
(1) Connector
(a) MR-JE-10A to MR-JE-100A
Receptacle
Connector
CNP1
09JFAT-SAXGDK-H5.0
(b) MR-JE-200A/MR-JE-300A
Receptacle
Connector
CNP1
07JFAT-SAXGFK-XL
CNP2
03JFAT-SAXGFK-XL
POINT
For the wire sizes used for wiring, refer to section 11.5.
CNP1
Table 3.1 Connector and applicable wire
assembly
Size
AWG 18 to 14
CNP1
CNP2
Table 3.2 Connector and applicable wire
assembly
Size
AWG 16 to 10
Servo amplifier
Applicable wire
Insulator OD
3.9 mm or shorter
Servo amplifier
Applicable wire
Insulator OD
4.7 mm or shorter
3 - 18
Stripped
Open tool
length [mm]
9
J-FAT-OT
Stripped
Open tool
length [mm]
11.5
J-FAT-OT-EXL
Manu-
facturer
JST
Manu-
facturer
JST

Hide quick links:

Advertisement

Table of Contents
loading