Parameter - Mitsubishi MR-JE-10A Instruction Manual

Servo amplifiers
Table of Contents

Advertisement

12. COMMUNICATION FUNCTION (MITSUBISHI GENERAL-PURPOSE AC SERVO PROTOCOL)

12.5.3 Parameter

(1) Specification of the parameter group
To read or write the parameter settings, etc., the group of the parameters to be operated must be
specified in advance. Write data to the servo amplifier as follows to specify the parameter group.
(2) Parameter group reading
The following shows how to read the parameter group set with slave station.
(a) Transmission
Transmit command [0] [4] and data No. [0] [1].
Command
[0] [4]
(b) Return
The slave station returns the preset parameter group.
(3) Reading symbols
The following shows how to read symbols of parameters. Specify a parameter group in advance. (Refer
to (1) of this section.)
(a) Transmission
Transmit the command [0] [8] and the data No. [0] [1] to [F] [F] corresponding to the parameter No.
(Refer to section 12.4.1.)
The data No. is expressed in hexadecimal. The decimal equivalent of the data No. value
corresponds to the parameter No.
(b) Return
The slave station returns the symbol of the parameter requested.
Command
Data No.
[8] [5]
[0] [0]
Data No.
[0] [1]
0
0
0
0 0 0
Transmission
data
0000
Basic setting parameters ([Pr. PA_ _ ])
0001
Gain/filter parameters ([Pr. PB_ _ ])
0002
Extension setting parameters ([Pr. PC_ _ ])
0003
I/O setting parameters ([Pr. PD_ _ ])
0004
Extension setting 2 parameters ([Pr. PE_ _ ])
0005
Extension setting 3 parameters ([Pr. PF_ _ ])
Parameter group
0: Basic setting parameters ([Pr. PA_ _ ])
1: Gain/filter parameters ([Pr. PB_ _ ])
2: Extension setting parameters ([Pr. PC_ _ ])
3: I/O setting parameters ([Pr. PD_ _ ])
4: Extension setting 2 parameters ([Pr. PE_ _ ])
5: Extension setting 3 parameters ([Pr. PF_ _ ])
Symbol characters (9 digits)
12 - 18
Parameter group

Hide quick links: