Show Controller - HP storageworks HSG80 Reference Manual

Array controller v8.7
Hide thumbs Also See for storageworks HSG80:
Table of Contents

Advertisement

CLI Command Descriptions

SHOW controller

Displays information about the specified controller.
Syntax
SHOW controller
Parameters
controller
Identifies which controller is displayed. Specify THIS_CONTROLLER (the one
connected to the CLI maintenance terminal) or OTHER_CONTROLLER.
Switches
The following switch is available for the SHOW controller command:
FULL
Example
To display the full information for a controller, enter:
SHOW OTHER_CONTROLLER FULL
Controller:
HSG80 (c) Compaq xxxxxxxxxx Software xxxxxx, Hardware xxxx
NODE_ID
ALLOCATION_CLASS = 1
SCSI_VERSION
Configured for MULTIBUS_FAILOVER with ZG95005203
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is lun 0 (NOIDENTIFIER)
Host Connection Table is NOT locked
Smart Error Eject Disabled
Host PORT_1:
Reported PORT_ID = 5000-1FE1-0005-9C13
PORT_1_TOPOLOGY
Host PORT_2:
Reported PORT_ID = 5000-1FE1-0005-9C14
PORT_2_TOPOLOGY
NOREMOTE_COPY
2–160
= 5000-1FE1-0005-9C10
= SCSI-2
= FABRIC (connection down)
= FABRIC (connection down)
HSG80 Array Controller V8.7 Command Line Interface Reference Guide