To create unit D5 from mirrorset MIRR1, and to let only two host connections
(Server1 and Server2) have access to this unit, enter:
ADD UNITS D5 MIRR1 DISABLE_ACCESS_PATH=ALL
SET UNITS D5 ENABLE_ACCESS_PATH=(SERVER1,SERVER2)
If the controller pair is in transparent failover mode, this unit is on port 1, and
is available only to host connections Server1 and Server2. Server1 and
Server2 must be connected to host port 1 to access the unit. The unit is
presented to each host connection as LUN (5 – offset). Offset is a host
connection characteristic, specified in the ADD (or SET) CONNECTIONS
command.
If the controller pair is in multiple-bus failover mode, this unit can potentially
be seen by all four controller ports, but is accessible only by host connections
Server1 and Server2. It is presented to each host connection as LUN (5 –
offset).
To create unit D7 from a RAIDset named RAID9 and instruct the unit to take
advantage of the controller's write-back caching feature, enter:
ADD RAIDSETS RAID9 DISK10100 DISK20100 DISK30100 DISK40100
INITIALIZE RAID9
ADD UNITS D7 RAID9 WRITEBACK_CACHE
See Also
CREATE_PARTITION
DESTROY_PARTITION
DELETE unit-number
SET unit-number
SHOW unit-number
SHOW UNITS
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
ADD UNITS
2–41