CLI Command Descriptions
Table 2–3: SET controller Switches (Continued)
PORT_1_AL_PA=n
PORT_2_AL_PA=n
PORT_1_TOPOLOGY=FABRIC
PORT_2_TOPOLOGY=FABRIC
PORT_1_TOPOLOGY=LOOP_HARD
PORT_1_TOPOLOGY=LOOP_SOFT
PORT_1_TOPOLOGY=OFFLINE
PORT_2_TOPOLOGY=LOOP_HARD
PORT_2_TOPOLOGY=LOOP_SOFT
PORT_2_TOPOLOGY=OFFLINE
PROMPT="new prompt"
REMOTE_COPY=node-name
NOREMOTE_COPY
SCSI_VERSION=SCSI-2
SCSI_VERSION=SCSI-3
SMART_ERROR_EJECT
TERMINAL_PARITY
NOTERMINAL_PARITY
TERMINAL_SPEED
TIME
UPS=NODE_ONLY
UPS=DATACENTER_WIDE
NOUPS
ALLOCATION_CLASS
Allocation class is a unique identification number assigned to the controller pair
under certain operating systems. The value for an allocation class is
0-4294967295. I; for Compaq Tru64 UNIX, it is a 4-byte number. It is reported in
2–108
Switch
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
Values
0-EF (hexidecimal); factory
defaults: port 1 is 71 and
port 2 is 72
None
None
1-16 characters
None
None
Disable
Enable
Odd or even, no terminal
parity (default)
4800, 9600 (default), or
19200
Two-digit day,
three-character month,
four-digit year, and
two-digit hour, minute, and
second
None