Show Mirrorset-Name - HP storageworks HSG80 Reference Manual

Array controller v8.7
Hide thumbs Also See for storageworks HSG80:
Table of Contents

Advertisement

Specify READ_SOURCE=LEAST_BUSY to direct read requests to the
mirrorset disk with the least amount of work in its queue. If multiple disks
have equally short queues, the controller queries normal disks for each read
request as it would when READ_SOURCE=ROUND_ROBIN is specified.
Specify READ_SOURCE=ROUND_ROBIN to sequentially direct read
requests to each local mirrorset disk. The controller equally queries all normal
disks for each read request.
Examples
To create a mirrorset named MIRR1 consisting of disks DISK10000, DISK20100, and
DISK30200, enter:
ADD MIRRORSETS MIRR1 DISK10000 DISK20100 DISK30200
To create a host-addressable unit after the mirrorset MIRR1 has been created, enter:
INITIALIZE MIRR1
ADD UNITS D104 MIRR1
See Also
ADD DISKS
ADD UNITS
DELETE container-name
INITIALIZE
MIRROR
REDUCE

SHOW mirrorset-name

SHOW MIRRORSETS
SHOW STORAGESETS
UNMIRROR
HSG80 Array Controller V8.7 Command Line Interface Reference Guide
ADD MIRRORSETS
2–17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents