CLI Command Descriptions
CLEAR_ERRORS unit-number UNWRITEABLE_DATA
Clears an unwriteable data error on a unit.
This command affects all partitions on the same container.
If a storageset or disk drive fails before its data has been written to it, the controller
reports an unwriteable data error. The CLEAR_ERRORS unit-number
UNWRITEABLE_DATA command removes the data from the cache and clears the
unwriteable data error.
CAUTION: This command will cause data loss.
Syntax
CLEAR_ERRORS unit-number UNWRITEABLE_DATA
IMPORTANT: Because misuse of this command will cause data loss, the command cannot be
abbreviated.
Parameters
unit-number
Identifies the unit having the unwriteable data error. The unit-number is the name
given to the unit when it was created with the ADD UNITS command.
Switches
There are no switches associated with this command.
Example
To clear the unwriteable data error on disk unit D103, enter:
CLEAR_ERRORS D103 UNWRITEABLE_DATA
2–48
HSG80 Array Controller V8.7 Command Line Interface Reference Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents