Download Print this page

Removing A Controller - HP StorageWorks HSG60 Installation Instructions Manual

Advertisement

Replacing HSG60 and HSG80 controllers
in single-controller configurations
Use the steps in
"Removing a
a
controller" on page 4 to replace a controller in a
single-controller configuration.
Caution:
Static electricity can easily damage an array
controller. Wear a snug-fitting, grounded ESD wrist strap.

Removing a controller

Perform the following steps to remove a controller in a
single-controller configuration:
1. Connect a PC or terminal to the controller maintenance port
(see
Figure
4) if the controller is operational. If the
controller is not operational, proceed to
Figure 4: Connecting PC and terminal cables to the controller
maintenance port (dual-redundant configuration shown)
2. From the host console, halt all host activity to the
controller, and dismount the logical units in the subsystem.
3. If you are using Microsoft
2000, shut down the server.
4. Run the Fault Management Utility (FMU) to obtain the last
failure codes, if necessary.
5. Determine whether the disk was initialized with the
SAVE_CONFIGURATION switch, and then perform one of
the following options:
If the disk was not initialized with the
SAVE_CONFIGURATION switch, locate existing
information that will support the manual configuration
of the subsystem, and then proceed to
If the disk was initialized with the
SAVE_CONFIGURATION switch, enter the following
Command Line Interpreter (CLI) command from the
controller prompt to save the current device
configuration (for "this controller"):
CONFIGURATION SAVE
6. Shut down "this controller" with the following command:
SHUTDOWN THIS_CONTROLLER
controller" below and
"Installing
step
7.
®
Windows
®
NT
®
or Windows
step
6.
Note:
After the controller shuts down, the Reset button and the first
three LEDs turn on (see
occur, depending on the amount of data that needs to be flushed
from the cache module. Proceed only after the Reset button stops
flashing and remains on.
1
1 Reset button
Figure 5: Controller LEDs and Reset button
Caution:
the controller crashes and it is not shut down with the
SHUTDOWN THIS_CONTROLLER command. Loss of data
can occur.
7. Remove the program card ESD cover (see
program card, and then save them in an antistatic bag or on
a grounded antistatic mat for the replacement controller.
5035
1 Program card slot Eject button
2 Program card
3 ESD cover
Figure 6: Removing the controller ESD cover
Page 3
Figure
5). This can take several minutes to
2
1
2
3
4
2 First three LEDs
The cache module may contain unwritten data if
1
2
5
6
5021
Figure
6) and the
3
5024

Advertisement

loading

This manual is also suitable for:

Storageworks hsg80