HP storageworks HSG80 Reference Manual page 46

Array controller v8.7
Hide thumbs Also See for storageworks HSG80:
Table of Contents

Advertisement

CLI Command Descriptions
ADD STRIPESETS
Names a stripeset and adds it to the controller configuration. A stripeset can contain
from 2 to 24 members. Stripesets are also referred to as RAID level 0 storagesets. The
number of members in the stripeset is determined by the number of container-name
parameters specified.
NOTE: The maximum size of a stripeset is 1.024 TB (1024 GB). The size of a stripeset is
approximated by multiplying the size of the smallest member by the number of members in the
stripeset.
Syntax
ADD STRIPESETS stripeset-name container-name1 container-name2
[container-nameN]
Parameters
The following parameters are required for the ADD STRIPESETS command:
stripeset-name
container-name
These parameters are described in the following paragraphs:
stripeset-name
Assigns a name to the stripeset. This is the name used with the ADD UNITS
command to identify the stripeset as a host-addressable unit.
The stripeset-name may consist of up to nine characters excluding commas and
back-slashes.
It is common to name a stripeset STRIPEn, where n is a sequentially assigned,
unique identifier. This naming convention presents to the user both the type of
container and its unique identifier.
container-name1 container-name2 [container-nameN]
Identifies the members (disk drives or mirrorsets) making up the stripeset.
Stripesets can contain between 2 and 24 members.
NOTE: A 256-character limit exists for the command line. If configuring a stripeset with many
members, consider renaming the members to shorter names in order to enter the entire
command line.
2–30
HSG80 Array Controller V8.7 Command Line Interface Reference Guide

Hide quick links: