ADD SPARESETS
Adds a disk drive to the spareset and initializes the metadata on the drive.The spareset
is a pool of drives available to the controller to replace failing storageset members.
Syntax
ADD SPARESETS disk-name
Parameters
disk-name
Indicates the name of the disk drive being added to the spareset. Only one disk
drive can be added to the spareset with each ADD SPARESETS command.
Switches
There are no switches associated with this command.
Example
To add disk drives named DISK20200 and DISK30300 to a spareset, enter:
ADD SPARESETS DISK20200
ADD SPARESETS DISK30300
See Also
DELETE SPARESETS
SHOW SPARESETS
SHOW STORAGESETS