CLI Command Descriptions
ADD PASSTHROUGH
Names a pass through device and adds it to the controller configuration. This
command is typically used when pass through devices are added to a previously
configured subsystem. During initial setup, the entire device set is customarily added
to the controller's configuration through the CONFIG utility.
NOTE: The controller supports a maximum of 84 physical storage devices, even though more
than 84 target IDs are available. Do not exceed the maximum number of physical devices in the
subsystem.
Syntax
ADD PASSTHROUGH passthrough-name scsi-port-target-lun
Parameters
The following parameters are required for the ADD PASSTHROUGH command:
passthrough-name
scsi-port-target-lun
These parameters are described in the following paragraphs:
passthrough-name
Assigns a name to the passthrough device. This container name is then used with
the ADD UNITS command to create a logical unit.
The passthrough-name may consist of a maximum of nine printable characters
excluding commas and back-slashes.
A passthrough device is commonly named PASSpttll, where pttll is the disk
Port-Target-LUN address. Although other naming conventions are acceptable, this
naming convention presents the type of passthrough device and the passthrough
device SCSI location.
scsi-port-target-lun
Indicates the SCSI device PTL address. Place at least one space between the port
number, target number, and the LUN number when entering the PTL address.
port—Designates the SCSI device port number, from 1 to 6, on which the
passthrough device resides.