Chapter 4 Performing Calibration
Figure 9
Procedure
1
2
3
4
5
6
Figure 10
38
e-Calibration connection diagram with an extension cable
JD723C/724C
Connect an extension cable, if necessary, to the RF Out / Reflection port of the instrument.
Connect the EZ-Cal to the instrument's the RF Out / Reflection port or at the end of the extension
cable if used.
Connect the USB cable to the side of the EZ-Cal and then to the USB Host port to power the
e-calibration kit.
Press the CAL hard key.
The on-screen instruction appears to guide you through the e-calibration.
Do the following depending on your instrument model and its installed option:
JD723C, JD724C, and JD726C without 2-port transmission option: Tap the Continue button.
The calibration progress bar appears.
JD725C and JD726C with 2-port transmission option: Tap the O-S-L button.
The calibration progress bar appears.
Check the screen to see if the calibration status is now changed to
e-Calibration on JD724C using EZ-Cal kit
CellAdvisor JD720C User's Manual
JD725C/726C
CAL ON