No.
o2-04
E2-11
b3-04
V/f Gain during Speed Search
b3-06
Output Current 1 during Speed Search
Output Current 2 during Speed Search
b3-07
(Speed Estimation Type)
b3-26
Start Speed Search Select
b8-03
Energy Saving Control Filter Time Constant
b8-04
Energy Saving Coefficient Value
C5-17
Motor Inertia
C6-02
Carrier Frequency Selection
E2-01
Motor Rated Current
E2-02
Motor Rated Slip
E2-03
Motor No-Load Current
E2-05
Motor Line-to-Line Resistance
E2-06
Motor Leakage Inductance
E2-10
Motor Iron Loss for Torque Compensation
L2-02
Momentary Power Loss Ride-Thru Time
L2-03
Momentary Power Loss Minimum Baseblock Time
L2-04
Momentary Power Loss Voltage Recovery Time
L3-24
Motor Acceleration Time for Inertia Calculations
L8-02
Overheat Alarm Level
L8-35
Installation Method Selection
L8-38
Carrier Frequency Reduction Selection
n1-03
Hunting Prevention Time Constant
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Name
Model CIMR-Po
Drive Model Selection
Motor Rated Power
B.16 Defaults by Drive Model
Unit
Default Settings
2A0040
2A0056
Hex.
6B
6D
kW
11
15
(HP)
(15)
(20)
%
100
100
0.5
0.5
s
0.50
0.50
70.44
63.13
2
kgm
0.053
0.076
7
7
A
39.7
53
Hz
1.7
1.6
A
11.2
15.2
Ω
0.23
0.138
%
19.5
17.2
W
245
272
s
1
2
s
0.9
1
s
0.3
0.6
s
0.265
0.244
°C
125
120
2
2
2
2
ms
10
10
2A0069
2A0081
6E
6F
18.5
22
(25)
(30)
100
100
0.5
0.5
0.50
0.50
57.87
51.79
0.138
0.165
7
7
65.8
77.2
1.67
1.7
15.7
18.5
0.101
0.079
15.7
19.5
505
538
2
2
1
1
0.6
0.6
0.317
0.355
120
125
2
2
2
2
10
10
B
489