A.4 Drive Derating Data
Drive Model
5A0125
5A0145
5A0192
5A0242
u

Temperature Derating

To ensure the maximum performance life, the drive output current must be derated as shown in
installed in areas with high ambient temperature or if drives are mounted side-by-side in a cabinet. In order to ensure reliable
drive overload protection, set parameters L8-12 and L8-35 according to the installation conditions.
n
Parameter Settings
No.
Ambient
L8-12
Temperature Setting
Installation Method
L8-35
Selection
<1> Default setting is determined by drive model.
Setting 0: (Models 2A0250 to 2A0415 and 4A0208 to 4A0675)
Setting 2: (Models 2A0004 to 2A0211, 4A0002 to 4A0165, and 5A0003 to 5A0242).
Setting 0: IP00/Open-Chassis Enclosure
Drive operation between -10 °C and +50 °C allows 100% continuous current without derating.
Setting 1: Side-by-Side Mounting
Drive operation between -10 °C and +30 °C allows 100% continuous current without derating. Operation between +30 °C and
+50 °C requires output current derating.
Setting 2: IP20/NEMA 1, UL Type 1 Enclosure
Drive operation between -10 °C and +40 °C allows 100% continuous current without derating. Operation between +40 °C and
+50 °C requires output current derating.
Setting 3: External Heatsink Installation
Drive operation between -10 °C and +40 °C allows 100% continuous current without derating. Operation between +40 °C and
+50 °C requires output current derating.
428
Name
Adjust the drive overload (oL2) protection level when the drive is installed
in an environment that exceeds its ambient temperature rating.
0: IP00/Open-Chassis Enclosure
1: Side-by-Side Mounting
2: IP20/NEMA Type 1 Enclosure
3: External Heatsink Installation
Drive Rating
(%)
100
85
70
55
L8-35 = 1: Side-by-Side Mounting
0
-10
Figure A.1 Ambient Temperature and Installation Method Derating
Three-Phase 600 V Class
Normal Duty Rating (ND)
2 kHz
125.0
145.0
192.0
242.0
Description
L8-35 = 0: IP00/Open-Chassis
Enclosure
L8-35 = 2: IP20/NEMA 1,
L8-35 = 3: External Heatsink
L8-12
(Ambient temp: °C)
30
40
50
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Rated Current [A]
Figure A.1
UL Type 1 Enclosure
lnstallation
3 kHz
93.0
108.0
148.0
187.0
when the drive is
Range
Def.
-10 to +50
+40 °C
<1>
0 to 3