B.8 H Parameters: Multi-Function Terminals
H1-oo
Function
Setting
Forward run command
40
(2-Wire sequence)
Reverse run command
41
(2-Wire sequence)
Run command
42
(2-Wire sequence 2)
FWD/REV command
43
(2-Wire sequence 2)
47
Node setup
51
Sequence Timer Disable
52
Sequence Timer Cancel
60
DC Injection Braking command
External Speed Search
61
command 1
External Speed Search
62
command 2
63
Field weakening
65
KEB Ride-Thru 1 (N.C.)
66
KEB Ride-Thru 1 (N.O.)
67
Communications test mode
68
High Slip Braking (HSB)
6A
Drive enable
75
Up 2 command
76
Down 2 command
7A
KEB Ride-Thru 2 (N.C.)
7B
KEB Ride-Thru 2 (N.O.)
A8
Secondary PI Disable (N.O.)
A9
Secondary PI Disable (N.C.)
AA
Secondary PI Inverse Operation
AB
Secondary PI Integral Reset
AC
Secondary PI Integral Hold
AD
Select Secondary PI Parameters
AF
Emergency Override Forward Run Closed: Run the drive forward using the speed set in S6-02.
B0
Emergency Override Reverse Run Closed: Run the drive in reverse using the speed set in S6-02.
<1> Available in drive software versions PRG: 8502 and earlier.
456
H1 Multi-Function Digital Input Selections
Open: Stop
Closed: Forward run
Note:
Cannot be set together with settings 42 or 43.
Open: Stop
Closed: Reverse run
Note:
Cannot be set together with settings 42 or 43.
Open: Stop
Closed: Run
Note:
Cannot be set together with settings 40 or 41.
Open: Forward
Closed: Reverse
Note:
Determines motor direction, but does not issue a Run command. Cannot be set
together with settings 40 or 41.
Closed: Node setup for SI-S3 enabled.
Closed: Drive ignores sequence timers and runs normally (based on b1-02/b1-16 source).
Closed: When the input changes from open to closed, the currently active sequence timer is
disabled. Operation will resume with the next scheduled sequence timer. Cycling the Run
command after the current sequence timer has been canceled will re-enable the sequence
timer.
Closed: Triggers DC Injection Braking.
Closed: Activates Current Detection Speed Search from the maximum output frequency
(E1-04).
Closed: Activates Current Detection Speed Search from the frequency reference.
Closed: The drive performs Field Weakening control as set for d6-01 and d6-02.
Open: KEB Ride-Thru 1 enabled.
Closed: KEB Ride-Thru 1 enabled.
Tests the MEMOBUS/Modbus RS-422/RS-485 interface. Displays "PASS" if the test
completes successfully.
Closed: Activates High Slip Braking to stop the drive during a Run command.
Open: Drive disabled. If this input is opened during run, the drive will stop as specified by
b1-03.
Closed: Ready for operation.
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
Used to control the bias added to the frequency reference by the Up/Down 2 function. The
Up 2 and Down 2 commands must always be used in conjunction with one another.
Open: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB
Ride-Thru 2.
Closed: KEB Ride-Thru 2 enabled. Drive disregards L2-29 and performs Single Drive KEB
Ride-Thru 2.
Closed: Disables the secondary PI controller. Output behavior depends on the setting of
S3-12.
Closed: Enables the secondary PI controller. Output behavior depends on the setting of S3-12
when open.
Closed: Changes the sign of the secondary PI controller input (reverse acting PI control).
Closed: Resets the secondary PI controller integral value.
Closed: Locks the value of the secondary PI controller integral value.
Closed: Uses the secondary PI controller Proportional and Integral adjustments (S3-06 and
S3-07) instead of the primary PI controller Proportional and Integral adjustments (b5-02 and
b5-03). Only valid when S3-01 = 0 (secondary PI controller disabled).
Note:
This multi-function input has no effect on the secondary PI controller. It is only
used for the primary PI controller (b5-oo).
Description
YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual
Page
212
212
212
212
212
212
212
212
212
212
213
213
213
213
213
213
213
213
214
214
214
214
214
214
214
215
215
215

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents