REMOVING THE ELEVATOR MOTOR

7.
Removing the Elevator Motor
(1) Lower the paper feed tray fully, switch off the power, and pull out the print drum.
(2) Remove the covers.
• Front door
• Front cover
• Master-removal lower cover
(3) Squeeze the wire harness band [E] from the inside, detach from the side frame, and then unplug the
two connectors [F] of the Master removal unit.
(4) Remove the mounting screws (M4 x 6: 4 pcs), and hang free the Drive PCB [A] together with its
mounting bracket.
(5) Remove the Elevator springs [G] from both sides of the Paper feed tray to prevent the tray from
springing up.
(6) Remove the mounting screws (M4 x 8: 2 pcs), unplug the connector [D] of the Elevator motor [B], and
remove the Elevator motor [B].
A
A: Drive PCB
B: Elevator motor
C: Mounting screw
E
F
D: Connector of elevator motor
E: Wire harness band
4 – 16
RN (Version 1.0)
G
C
D
F: Connector of master removal unit
G: Elevator spring
B
C